Home / RBT Study Guide / Data Collection and Graphing / Discontinuous measurement: partial interval, whole interval and momentary time sampling

Domain A · Data Collection and Graphing · Task A.2

Discontinuous measurement: partial interval, whole interval and momentary time sampling

Discontinuous measurement samples behavior in intervals instead of recording every instance. Partial interval tends to overestimate how much a behavior occurred, whole interval tends to underestimate it, and momentary time sampling checks only the instant each interval ends.

Last reviewed November 10, 2026 against the BACB RBT Test Content Outline (3rd ed.)

What discontinuous measurement is

Discontinuous measurement records a sample of behavior, not every instance. You divide the observation into equal intervals (10 seconds, 30 seconds, 2 minutes) and mark each interval as an occurrence or a non-occurrence according to a rule. Task A.2 of the RBT Test Content Outline names three versions: partial interval, whole interval and momentary time sampling.

Supervisors choose these methods when continuous measurement is not practical: the behavior happens too fast to count, has no clear start and end, or you are teaching at the same time. The price is accuracy. Interval data is an estimate, and each method leans in a known direction.

The three methods

Partial interval recording

Mark the interval if the behavior occurred at any point during it, even for one second. It does not matter how many times it happened or how long it lasted. One mark per interval is the maximum. This method is usually chosen for behaviors the team wants to decrease, because it catches even brief instances.

Whole interval recording

Mark the interval only if the behavior occurred for the entire interval. If it stopped for even a moment, the interval is a non-occurrence. This method is usually chosen for behaviors the team wants to increase and that should be continuous, such as staying on task or staying seated.

Momentary time sampling

Look at the client at the moment the interval ends and mark whether the behavior is happening right then. What happened during the rest of the interval is not recorded. Because you only need to look at set moments, this is the one method that lets you teach, or observe more than one client, between checks.

In session

Jayden's timer buzzes every 60 seconds during independent work. At each buzz he glances at Priya and marks a plus if she is writing on her worksheet at that instant. Between buzzes he is free to run trials with another learner.

Which overestimates and which underestimates

Picture a 100-second observation split into ten 10-second intervals. Sam hums for 2 seconds in every interval, so he really hummed for 20 of the 100 seconds, or 20% of the time.

Partial interval has a second quirk. If Diego hits five times inside one interval, the interval still gets a single mark. So partial interval can overestimate how much of the session a behavior filled while underestimating how many times it happened.

Common mix-up

Candidates often flip the two. A memory aid: partial gives credit for only part of an interval, so it is generous and overestimates. Whole demands the whole interval, so it is strict and underestimates.

Comparison table

MethodMark the interval whenTends toOften used forAttention needed
Partial intervalThe behavior occurs at any point in the intervalOverestimate how much of the time it occurredBehaviors to decreaseContinuous watching
Whole intervalThe behavior lasts the entire intervalUnderestimate how much of the time it occurredBehaviors to increaseContinuous watching
Momentary time samplingThe behavior is occurring at the instant the interval endsOver or underestimate, depending on the momentLonger-lasting behaviors such as on-task or engagementOnly at the end of each interval

Recording and reporting interval data

Interval data is reported as the percentage of intervals in which the behavior was scored. A 10-minute observation with 30-second intervals has 20 intervals. If Ava's vocal stereotypy is marked in 8 of them, the result is 8 / 20 = 0.40, or 40% of intervals.

Notice what that number is not. It is not "8 times" and it is not "40% of the session." Interval methods never give a true frequency or a true duration, so describe the result as a percentage of intervals. That figure is what gets entered and plotted on the graph.

Three habits keep interval data clean:

If the interval length or method on the data sheet does not seem to fit the behavior, tell your supervisor. Choosing or changing the method is the supervisor's decision.

How the exam tests it

A common question format describes how an RBT is scoring intervals and asks you to name the method. A second format asks which method overestimates or underestimates.

On the exam

Find the scoring rule in the scenario. "At any time during the interval" is partial interval. "Throughout the interval" or "for the full 10 seconds" is whole interval. "When the timer goes off" or "at the end of the interval" is momentary time sampling. If the scenario has tallies or a stopwatch and no intervals, the answer is a continuous measure.

For how this task sits beside the other seven in the domain, see the Domain A guide.

Practice questions

Original questions in the style of the exam. Pick an answer before you open the explanation.

1. Leo's plan targets staying on task. His RBT uses 15-second intervals and marks an interval only if Leo was on task for all 15 seconds. Which procedure is this?

  1. Partial interval recording
  2. Momentary time sampling
  3. Whole interval recording
  4. Total duration recording
Show answer

C. Whole interval recording

Scoring an interval only when the behavior lasts the entire interval is whole interval recording. Partial interval would score the interval if Leo was on task for any part of it, which is the usual confusion.

2. A timer vibrates every 2 minutes. Each time it does, the RBT looks up and marks whether Mia is in her seat at that instant. Which procedure is this?

  1. Momentary time sampling
  2. Partial interval recording
  3. Whole interval recording
  4. Continuous event recording
Show answer

A. Momentary time sampling

Momentary time sampling records whether the behavior is occurring at the moment the interval ends. Partial interval recording would require watching for the behavior throughout the whole 2 minutes, not just at the signal.

3. Partial interval recording is being used for brief, frequent hand biting. Compared with what really happened, the data will most likely do which of these?

  1. Underestimate how much of the session it occurred
  2. Show the exact number of times that it occurred
  3. Show the exact number of seconds that it lasted
  4. Overestimate how much of the session it occurred
Show answer

D. Overestimate how much of the session it occurred

A one-second bite marks the whole interval as an occurrence, so partial interval data tends to overestimate how much of the session the behavior filled. Interval data never gives an exact count or an exact duration.

Common questions

Does partial interval recording overestimate or underestimate behavior?

Partial interval recording tends to overestimate how much of the time a behavior occurred, because one brief instance marks the whole interval. It can also underestimate the number of responses when a behavior happens several times inside one interval, since the interval is still marked only once.

Why use discontinuous measurement instead of continuous measurement?

It is used when recording every instance is not practical, for example when a behavior happens at a very high rate, has no clear start and end, or the observer is also teaching. The tradeoff is that it produces an estimate and not an exact count or duration. The supervisor chooses the method.

What is the difference between whole interval recording and momentary time sampling?

In whole interval recording you watch for the entire interval and mark it only if the behavior continued the whole time. In momentary time sampling you look only at the moment the interval ends and mark whether the behavior is happening right then. Whole interval needs continuous attention and momentary time sampling does not.